Defi9 جهاز الصدمة
الاشارة القلبية ECG - عرض لتخطيط القلب مع تسجيل الاشارة القلبية , توفر اشارة معيارية 1ميلي فولط Ⅰ, Ⅱ, Ⅲ, Avr, Avl, Avf, V1~V6الليدات ( الأقطاب ) : -2
Read more
Multi-Parameter Defibrillator & Patient Monitor.
A compact, rugged, and lightweight professional biphasic defibrillator designed for reliable emergency cardiac care in hospitals, clinics, and other healthcare environments. The device combines manual biphasic defibrillation with comprehensive multi-parameter patient monitoring, providing clinicians with essential cardiac and physiological information in a single platform.
The integrated monitoring functions include ECG, SpO₂, NIBP, RESP, PR, and TEMP, supporting continuous assessment of the patient’s cardiovascular and vital physiological status during emergency and routine clinical care.
All Meditech professional healthcare customers can submit equipment service tickets through our Customer Service Portal.
To receive an additional 2 months of extended warranty, please register your products here.For all support resources and contact information, visit our Support hub.
Coming soon.
Discover the advanced capabilities that set our products apart
Detailed technical specifications and performance parameters
| Parameter | Specification |
|---|---|
| Defibrillator Type | Manual, Synchronized & Asynchronized Defibrillation |
| Output Waveform | Biphasic Technology |
| Energy Accuracy | < ±1% |
| Energy Selection | 0, 3, 5, 7, 10, 20, 30, 50, 100, 200, 300, 360 Joules (nominal at 50Ω resistance) |
| Recharge Time | Maximum 8 seconds to 360 Joules |
| Standard Adult/Pediatric Electrodes | Reusable external adult electrodes with integrated pediatric electrodes |
| Parameter | Specification |
|---|---|
| Display | 7-inch TFT color display |
| Parameter | Specification |
|---|---|
| ECG Leads | I, II, III, aVR, aVL, aVF, V1–V6 |
| ECG Monitoring | Multi-lead ECG monitoring with high-resolution waveform display |
| Parameter | Specification |
|---|---|
| Pulse Rate Range | 0–300 BPM |
| Pulse Accuracy | ±2 BPM |
| Parameter | Specification |
|---|---|
| Measurement Method | Automatic oscillometric |
| Working Modes | Manual / Automatic |
| Adult Measurement Range | 10–250 mmHg |
| Pediatric Measurement Range | 10–200 mmHg |
| Neonatal Measurement Range | 10–135 mmHg |
| Parameter | Specification |
|---|---|
| Measurement Range | 20–45°C |
| Parameter | Specification |
|---|---|
| Display Information | SpO₂ value, pulse histogram, waveform, pulse rate |
| Measurement Range | 0–99% for adult, pediatric, and neonatal patients |
| Probe Type | Standard adult finger clip sensor |
| Parameter | Specification |
|---|---|
| AED Function | Automatic rhythm analysis and charging with programmable automatic energy selection |
| Energy Selection | Automatic on-screen energy level selection with voice prompts |
| Shockable Rhythms | Ventricular fibrillation with amplitude ≥200μV |
| Ventricular tachycardia with rate ≥140 BPM and QRS duration ≥140ms | |
| Charge Control | Front panel control and paddle push button |
| User Guidance | Voice and visual prompts |
| Parameter | Specification |
|---|---|
| Paper Type | 50mm thermal paper |
| Printing Speed | 12.5mm/s, 25mm/s, 50mm/s |
| Print Delay | User selectable 6-second delay |
| Printing Method | High-resolution thermal print head |
| Print Modes | Manual or automatic, user configurable |
| ON/OFF Control | Front panel and paddle controls |
| Automatic Recording Function | 9-second recording triggered by alarm activation, defibrillator charging, or shock discharge |
Compatible accessories to extend functionality
Core specifications at a glance
الاشارة القلبية ECG - عرض لتخطيط القلب مع تسجيل الاشارة القلبية , توفر اشارة معيارية 1ميلي فولط Ⅰ, Ⅱ, Ⅲ, Avr, Avl, Avf, V1~V6الليدات ( الأقطاب ) : -2
Read moreIf there is any wrong shown in ECG data Kindly check The ECG cable pins
Read moreForma de onda de salida Defi9 : tecnología bifásica Tipo de desfibrilador: Manual, Sincronizado, Asincronizado Precisión de energía del desfibrilador: <+ 1% Defibrilador de selección de energía: 0,3,5,7,10,20,30,50,100,200,300,360 julios (nominal a una resistencia de 50) Tiempo de carga del desfibrilador: máximo de 8 segundos a 360 julios Tiempo de carga de la batería: Tiempo mínimo de 4 horas para una carga completa Capacidad de la batería: el 100% de la batería proporcionará 120 minutos de monitoreo; y 30 descargas a 360 julios
Read more