Defi® s , Pro Type Adult / Child Automated External Defibrillator/ AED ,
Child Mode:
30, 30, 50 Joule
50, 50, 75 Joule
Adult Mode:
120, 120, 150 Joule
150, 150, 200 Joule
2 language to choose by user
5 Sound level (max 100 dp) control by user
Meditech Defi series gives you the power to help save a life,
Safely delivers a shock only if needed
Child Mode:
30, 30, 50 Joule
50, 50, 75 Joule
Adult Mode:
120, 120, 150 Joule
150, 150, 200 Joule
2 language to choose by user
5 Sound level (max 100 dp) control by user
Meditech Defi series gives you the power to help save a life,
Safely delivers a shock only if needed
Advantages
2 Language to choose (by End user)
5 Levels of sound volume (by End user)
2 energy range to choose for Adult
2 energy range to choose for Child
Infra-red for data transmission (standard)
Daily, Weekly and Monthly self-test
Using the AED while in bag (dont need to open it)
Extra pocket in bag for first Aid products
IPX55 water and dust resistant
Features
Description shows the parameter information. ”OHM” represents the detected
2 Language to choose (by End user)
5 Levels of sound volume (by End user)
2 energy range to choose for Adult
2 energy range to choose for Child
Infra-red for data transmission (standard)
Daily, Weekly and Monthly self-test
Using the AED while in bag (dont need to open it)
Extra pocket in bag for first Aid products
IPX55 water and dust resistant
Features
- Three-step defibrillation process defibrillator
- Selectable Energy for different age patients
Child Mode:
30, 30, 50 Joule
50, 50, 75 Joule
Adult Mode:
120, 120, 150 Joule
150, 150, 200 Joule
30, 30, 50 Joule
50, 50, 75 Joule
Adult Mode:
120, 120, 150 Joule
150, 150, 200 Joule
- Extensive voice and visual prompts for the operator
- Changeable language manually
- Biphasic energy output
- Lock-out protection to prevent inadvertent defibrillation
- Device has an internal memory(60 hours)
- ECG signals and events can be transferred to the computer
- Defi®5s AED is provided with carrying case,Battery,Pad,software for data transmission
- It has long-life disposable LiMnO2 type battery (Battery life of at least 5 years)
-
- AED Storage Software (Standard configration)
Its used to assist upper supervisory system of Automatic External Defibrillator DEFI®
The interface display status information recorded in the running of the
AED, including type, event time, description, waves.
Event type includes on event, self-test event, analyzing event, charging event,
discharging event, CPR starting event, CPR stopping event. The event time displayed
is when the event happened.
Description shows the parameter information. ”OHM” represents the detected
impedance of the patient. Power parameter represents the voltage of the finished
charging; ”need to shock” represents that shock advised after analyzing ”no need to
shock” represents that no shock advised after analyzing.
Waveform represents the link of the ECG waves .
Waveform gain can be set as 5mm/mv、10mm/mv、20mm/mv;
Waveform speed can be set as 12.5mm/s、25mm/s、50mm/s:
Waveform speed can be set as 12.5mm/s、25mm/s、50mm/s:
Print ECG
Click the “print” in ECG waveform display interface, then enter the setting interface
of print.

Type: | Automatic External Defibrillator AED |
Self-test: | Daily, Weekly, Monthly |
Mode: | Adult, Child |
Waveform: | Biphasic truncated exponential |
Energy: | 200 Joule max. |
Energy Sequence: |
Programmable : Child Mode: 30, 30, 50 Joule 50, 50, 75 Joule Adult Mode: 120, 120, 150 Joule 150, 150, 200 Joule |
Charge time: (New, at 25℃) |
Less than 6 sec. to 150J Less than 8 sec. to 200J |
Voice Prompt: | Extensive voice prompt |
Visual Indicators: | LED prompts |
Control: | Two buttons: ON/OFF, Shock |
ECG storage: | 1500 events. |
Data transmission | Infrared |
Battery | |
Power: | 12V, 3000mAh |
Type: | Non-rechargeable |
Li-MnO2 Cell | |
Environmental | |
Operating Temperature |
0℃ to 40℃ |
Operating Humidity |
Relative humidity between 30% and 95% (non-condensing) |
Storage Temperature (without battery) |
-20℃ to 55℃ |
Storage Humidity (without battery) |
Up to 93% (non-condensing) |
Physical | |
Dimensions | |
Weight (with battery): |
1.9Kg (4.2 Pounds) |
Standard:
AED Pad .................... 1Pcs
Battery ...........................1Pcs
AED Case ...................... 1Pcs
Cleaning Cloth ................1Pcs
CD Software for ECG Data transfer
Options:
AED Cabinet
IrDA USB Adapter for ECG Data transfer
AED Pad .................... 1Pcs
Battery ...........................1Pcs
AED Case ...................... 1Pcs
Cleaning Cloth ................1Pcs
CD Software for ECG Data transfer
Options:
AED Cabinet
IrDA USB Adapter for ECG Data transfer
Product Features
-
Advantages
- Three-step defibrillation process defibrillator
- Selectable Energy for different age patients
- Extensive voice and visual prompts for the operator
- Changeable language manually
- Biphasic energy output
- Lock-out protection to prevent inadvertent defibrillation
- Device has an internal memory(60 hours)
- ECG signals and events can be transferred to the computer
- Defi®5s AED is provided with carrying case,Battery,Pad,software for data transmission
- It has long-life disposable LiMnO2 type battery (Battery life of at least 5 years)
-
- AED Storage Software (Standard configration)
2 Language to choose (by End user)
5 Levels of sound volume (by End user)
2 energy range to choose for Adult
2 energy range to choose for Child
Infra-red for data transmission (standard)
Daily, Weekly and Monthly self-test
Using the AED while in bag (dont need to open it)
Extra pocket in bag for first Aid products
IPX55 water and dust resistant
Features
Child Mode:
30, 30, 50 Joule
50, 50, 75 Joule
Adult Mode:
120, 120, 150 Joule
150, 150, 200 Joule
30, 30, 50 Joule
50, 50, 75 Joule
Adult Mode:
120, 120, 150 Joule
150, 150, 200 Joule
Its used to assist upper supervisory system of Automatic External Defibrillator DEFI®
The interface display status information recorded in the running of the
AED, including type, event time, description, waves.
Event type includes on event, self-test event, analyzing event, charging event,
discharging event, CPR starting event, CPR stopping event. The event time displayed
is when the event happened.
Description shows the parameter information. ”OHM” represents the detected
impedance of the patient. Power parameter represents the voltage of the finished
charging; ”need to shock” represents that shock advised after analyzing ”no need to
shock” represents that no shock advised after analyzing.
Waveform represents the link of the ECG waves .
Waveform gain can be set as 5mm/mv、10mm/mv、20mm/mv;
Waveform speed can be set as 12.5mm/s、25mm/s、50mm/s:
Waveform speed can be set as 12.5mm/s、25mm/s、50mm/s:
Print ECG
Click the “print” in ECG waveform display interface, then enter the setting interface
of print.

Product Specifications
Related Accessories
Related items

Defi® 5
Automatic(Automated) External Defibrillator AED,easy to use defibrillation device .Defi5 AED lightweight,mobile and can be used in situations where there could be several minutes before the arrival of advanced life support(ALS)