12.1-Inch Touch Screen Modular Patient Monitor with ECG, SpO₂, NIBP & EtCO₂ Expansion.
All Meditech professional healthcare customers can submit equipment service tickets through our Customer Service Portal.
To receive an additional 2 months of extended warranty, please register your products here.For all support resources and contact information, visit our Support hub.
Coming soon.
Discover the advanced capabilities that set our products apart
Detailed technical specifications and performance parameters
| Parameter | Specification |
|---|---|
| Lead Mode | 5 Leads (R, L, F, N, C / RA, LA, LL, RL, V) |
| Lead Selection | I, II, III, aVR, aVL, aVF, V |
| Waveform Display | 2 Channels |
| Derivative Mode | 3 Derivatives (R, L, F / RA, LA, LL) |
| Line Selection | I, II, III |
| Gain | ×2.5, ×5, ×10, ×20 mm/mV, Auto |
| Heart Rate Range | Adult: 15–300 bpm / Pediatric-Neonatal: 15–350 bpm |
| HR Accuracy | ±1% or ±1 bpm |
| Resolution | 1 bpm |
| Sensitivity | >200 μV |
| Differential Input Impedance | >5 MΩ |
| CMRR | Monitoring: >105 dB / Operation: >105 dB / Diagnostics: >85 dB |
| Electrode Offset Potential | ±300 mV |
| Leakage Current | <10 μA |
| Baseline Recovery | <3 s after defibrillation |
| ECG Signal Range | ±8 mV (Vp-p) |
| Bandwidth | Surgery: 1–15 Hz / Monitoring: 0.5–35 Hz / Diagnostic: 0.05–100 Hz |
| Calibration Signal | 1 mV ±5% |
| ST Monitoring Range | -2.0 to +2.0 mV |
| Arrhythmia Detection | ASYSTOLE, VFIB/VTAC, COUPLET, BIGEMINY, TRIGEMINY, R ON T, VT >2, PVC, TACHY, BRADY, MISSED BEATS, PNP, PNC |
| Parameter | Specification |
|---|---|
| Measurement Method | Impedance between RF (RA-LL) |
| Differential Input Impedance | >2.5 MΩ |
| Measurement Impedance Range | 0.3–5.0 Ω |
| Baseline Impedance Range | 0–2.5 kΩ |
| Bandwidth | 0.3–2.5 Hz |
| Respiratory Rate Range | Adult: 0–120 rpm / Pediatric-Neonatal: 0–150 rpm |
| Resolution | 1 rpm |
| Accuracy | ±2 rpm |
| Apnea Alarm | 10–40 s |
| Parameter | Specification |
|---|---|
| Measurement Method | Oscillometric |
| Modes | Manual / Automatic / STAT |
| Auto Measurement Interval | 1, 2, 3, 4, 5, 10, 15, 30, 60, 90, 120, 180, 240, 480 min |
| STAT Mode Duration | 5 min |
| Pulse Rate Range | 40–240 bpm |
| Alarm Type | SYS, DIA, MEAN |
| Patient Type | SYS | DIA | MEAN |
|---|---|---|---|
| Adult | 40–270 mmHg | 10–215 mmHg | 20–235 mmHg |
| Pediatric | 40–200 mmHg | 10–150 mmHg | 20–165 mmHg |
| Neonatal | 40–135 mmHg | 10–100 mmHg | 20–110 mmHg |
| Parameter | Specification |
|---|---|
| Resolution | 1 mmHg |
| Accuracy | Maximum mean deviation ±5 mmHg; Standard deviation ±8 mmHg |
| Overpressure Protection | Adult: 297±3 mmHg / Pediatric: 240±3 mmHg / Neonatal: 147±3 mmHg |
| Parameter | Specification |
|---|---|
| Measuring Range | 0–100% |
| Alarm Range | 0–100% |
| Resolution | 1% |
| Accuracy | 70–100%: ±2% / 0–69%: Not specified |
| Update Interval | Approx. 1 s |
| Alarm Delay | 10 s |
| Pulse Rate Range | 0–254 bpm |
| Pulse Rate Resolution | 1 bpm |
| Pulse Rate Accuracy | ±2 bpm |
| Parameter | Specification |
|---|---|
| Channels | 1 Channel |
| Measuring & Alarm Range | 0–50°C |
| Resolution | 0.1°C |
| Accuracy | ±0.1°C |
| Update Interval | Approx. 1 s |
| Average Time Constant | <10 s |
| Parameter | Specification |
|---|---|
| Supported Channels | ART, PA, CVP, RAP, LAP, ICP, P1, P2 |
| Channel | Range |
|---|---|
| ART | 0–300 mmHg |
| PA | -6–120 mmHg |
| CVP / RAP / LAP / ICP | -10–40 mmHg |
| P1 / P2 | -10–300 mmHg |
| Parameter | Specification |
|---|---|
| Pressure Sensor Sensitivity | 5 μV/V/mmHg |
| Impedance | 300–3000 Ω |
| Resolution | 1 mmHg |
| Accuracy | ±2% or ±1 mmHg |
Compatible accessories to extend functionality
Core specifications at a glance