Searching…
    Home Product Infusion Pumps MDS50

    MDS50

    Smart Volumetric Infusion Pump with Drug Library, High-Precision Flow Control & Advanced Safety Alarms

    The Smart Volumetric Infusion Pump is a high-accuracy infusion device designed for safe and reliable intravenous fluid and medication delivery in hospitals and critical care environments. Featuring precise flow control, a large drug library, automatic calibration capability, and comprehensive alarm protection, it ensures accurate infusion management while improving clinical efficiency and patient safety.

    With a user-friendly 2.8-inch TFT LCD display, built-in rechargeable battery, adjustable pressure and bubble detection settings, and multiple mounting options, it is suitable for ICU, emergency, operating room, and general ward applications

    CE CE Marked
    LATEX Not made with natural rubber latex
    ABS Made by ABS

    Product Features

    Discover the advanced capabilities that set our products apart

    High-Precision Infusion Control

    • High-accuracy flow regulation for reliable medication and fluid delivery.
    • Flow accuracy:
      • ±5% after calibration
      • Mechanical accuracy: ±2%
    • Supports infusion rates from 1–1200 mL/h.

    Intelligent Drug Management

    • Built-in 2000+ entries drug library.
    • Supports customized medication management.
    • Compatible with most standard IV sets.
    • New IV sets can be calibrated for improved accuracy.

    User-Friendly Operation

    • 2.8-inch TFT LCD display
      • Real-time infusion information
      • Remaining infusion time display
    • Infusion start reminder function.
    • Automatic parameter saving after power-off.
    • Multi-angle IV pole mounting bracket for flexible installation.

    Flexible Infusion Functions

    • Infusion volume setting:
      • 1–9999 mL
    • Total volume display:
      • 0–9999.9 mL
    • Adjustable KVO rate:
      • 1–5 mL/h
    • Three adjustable pressure levels:
      • High
      • Medium
      • Low

    Advanced Safety & Alarm System

    • Audible alarms for:
      • End of infusion
      • Occlusion/blockage
      • Door open
    • Visual and audible alarms for:
      • Air bubbles
      • Incorrect settings
      • Low battery
      • AC power failure
    • Automatic infusion stop during critical alarms.
    • Adjustable bubble detection and pressure thresholds.
    • Free-flow protection through IV set clamp.
    • Anti-bolus system prevents sudden excessive fluid delivery after occlusion release.

    Power Supply

    • AC/DC dual power operation.
    • Built-in rechargeable lithium battery.
    • Suitable for continuous hospital use and transport applications.

    Applications

    • Intensive Care Unit (ICU)
    • Operating Room
    • Emergency Department
    • Neonatal & Pediatric Care
    • General Hospital Wards
    • Medication and IV Fluid Therapy

    Product Specifications

    Detailed technical specifications and performance parameters

    Parameter Specification
    Applicable Syringe Size 10ml, 20ml, 30ml, 50/60ml
    Flow Rate Range 10ml syringe: 0.1–300 ml/h 20ml syringe: 0.1–600 ml/h 30ml syringe: 0.1–900 ml/h 50/60ml syringe: 0.1–1500 ml/h
    Flow Rate Accuracy Within ±3% (after calibration)
    Bolus Rate & Volume 10ml syringe: 0.1–240 ml/h, 0.1–5 ml 20ml syringe: 0.1–480 ml/h, 0.1–10 ml 30ml syringe: 0.1–720 ml/h, 0.1–10 ml 50/60ml syringe: 0.1–1200 ml/h, 0.1–10 ml
    KVO Rate 0.1–5.0 ml/h
    VTBI (Volume To Be Injected) 0.1–9999.9 ml
    Cumulative Volume 0.1–9999.9 ml
    Anti-Bolus Function Automatically releases tubing pressure when occlusion occurs
    Occlusion Pressure Settings High: 800 ±200 mmHg Medium: 500 ±100 mmHg Low: 300 ±100 mmHg
    Alarm Information Injection finished Injection nearly finished Occlusion detected Syringe disengagement Syringe installation error Forgotten operation Low battery Battery exhausted Abnormal running status Equipment failure System power down
    Power Source AC: 100–240V, 50/60Hz Internal Li-ion battery: 11.1V, ≥1800mAh Battery backup: Approx. 4 hours at 5 ml/h External DC: 12V
    Power Consumption 18VA
    Protection Classification Class II, internally powered equipment, Type BF applied part
    Water Protection Level IPX1
    Connector Interface DC 12V, RS232
    Drug Library Up to 1000 drugs
    Dimensions 280mm (L) × 200mm (W) × 112mm (H)
    Weight Approx. 2.2 kg
    Operating Temperature +5°C to +40°C
    Operating Humidity 20%–90% RH
    Storage Temperature -30°C to +55°C
    Storage Humidity ≤95% RH

    Related Accessories

    Compatible accessories to extend functionality

    Standard Accessories

    Accessory Quantity
    Infusion Pump Unit 1 Pcs
    AC Power Cable / Adapter 1 Pcs
    Cleaning Cloth 1 Pcs

    Product Overview

    Core specifications at a glance

    SKU MDT08-D00002
    Gross Weight 2.5kg
    Package Size 26×24×31.5cm
    QTY/BOX 1pcs