    DefiXpress Defibrillator Technical Specification

    June 2026 2 min read

    Meditech Debrillator Monitor can work both in Automated External Debrillator (AED) mode and Manual mode and record parameters of ECG, HR and SpO2

    Meditech Debrillator Monitor can work both in Automated External Debrillator (AED) mode and Manual mode and record parameters of ECG, HR and SpO2. Features: ·
    Works both in automated external debrillator (AED) and Manual modes · Records ECG, HR and SpO2 · It has voice and visual prompts for charge prompt and shockable rhythm · It has a high-resolution display and a thermal printer

    Display:7 screen(17.7cm)diagonally
    Sweep speed:25mm/ sec
    Number of leads for ECG:3-lead ECG cable or 5-lead ECG cable, paddles
    Output:Biphasic
    Energy sequence:Monitor display indicates both selected and delivered energy
    Charge time:<7sec with a new fully charged battery
    Charge prompts:Voice and visual prompts
    Electrode impedance measurement range:0-250Ω
    Lead selection:Displayed on monitor, paddles, I, II, III, AVR, AVL, AVF, V
    ECG size:0.25, 0.5, 1, 1.5, 2, 4 cm/mV display on monitor
    Heart rate:20-300bpm
    Heart rate alarm:On/Off displayed on monitor, user-selectable
    Smart alarm:Beeper/voice prompts indicate shockable rhythm
    SpO2 measurement range:30~100%, ±2% between 80%~90%, others ±5%
    Alarm range for SpO2 measurement range:User set high limit and low limit
    Alarm accuracy for SpO2 measurement range:±10% within setting values
    Alarm time accuracy for SpO2 measurement range:Less than 12secs
    Functions of AED mode:Auto analyse and charge x3 with programmable auto energy level selection, screen prompts, and voice prompts
    Shockable rhythms of AED mode:Ventricular fibrillation with amplitude >=200uV ventricular tachycardia with rates >=140bpm QRS complex wave duration >=140ms
    Charge control of AED mode:Control on device front panel, press key on paddle
    Prompts of AED mode:Voice and visual prompts
    Energy selection of Manual mode:Selectable at 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 joules
    Synchronization of Manual mode:Synchronizes defibrillator pulse to patient’s R-wave. ”SYNC” message displayed on monitor
    Printer paper:50mm thermal paper
    Paper speed:12.5mm/sec, 25mm/sec, 50mm/sec. User-selectable 6-second delay
    Printing method:High-resolution, thermal print head
    Print-out modes:Manual or automatic, user-configurable
    On/Off control:Front panel and paddle
    Automatic function:9-seconds recording initiated by alarm activation or defibrillator charge or defibrillator discharge
    Battery:Rechargeable, Ni-MH battery, 12V
    Battery life:For a new, fully charged battery- 60 defibrillator discharges at maximum energy, or 3 hours minimum of continuous ECG monitoring. Additional parameters will effect operating time with different functions
    Share:

    More from News & Events

    View all articles
    Meditech library
    Meditech library Aug 2026

    MD901F vs MD901F-Android Fetal Maternal Monitor Comparison Table

      Parameter MD901F MD901F-Android Type 12.1 inch 12.1 inch Standard Configuration FHR, TOCO, FM FHR, TOCO, FM, Touch Screen, Networking…

    Read more 2 min
    Product Library
    Product Library Jun 2026

    iBreathe TOUCH SCREEN SPIROMETER med inbyggd skrivare

    iBreathe TOUCH SCREEN SPIROMETER med inbyggd skrivare Bärbar enhet för lungfunktionstestning Denna spirometer använder differentialtrycksteknik för att noggrant mäta över…

    Read more 2 min
    Product Library
    Product Library Jun 2026

    How AED pads are manufactured?

    How AED pads are manufactured The production of AED pads is a meticulous process involving several stages to ensure their…

    Read more 2 min