Advanced NIBP Simulator for Patient Monitor Verification, Calibration & Biomedical Testing.
The S-bplink NIBP Simulator is a professional medical testing device designed for accurate verification, calibration assistance, and performance evaluation of NIBP monitors, patient monitors, and blood pressure measurement devices.
It provides realistic non-invasive blood pressure simulations, pressure measurement verification, leak testing, and safety valve testing for both adult and neonatal applications. With a user-friendly interface, 4.3-inch 65K color LCD display, built-in air chamber, and multiple simulation modes, the MS-200 is an essential tool for biomedical engineers and medical equipment service teams.
All Meditech professional healthcare customers can submit equipment service tickets through our Customer Service Portal.
To receive an additional 2 months of extended warranty, please register your products here.For all support resources and contact information, visit our Support hub.
Coming soon.
Discover the advanced capabilities that set our products apart
Supports connection with different NIBP devices through:
Displays pressure measurements in:
✓ NIBP simulation
✓ Patient monitor verification
✓ Blood pressure monitor testing
✓ Pressure leak testing
✓ Relief valve verification
✓ Pressure gauge calibration testing
✓ Pressure source output
✓ Performance evaluation
✓ Troubleshooting assistance
Detailed technical specifications and performance parameters
| Category | Features |
|---|---|
| Design | Compact, lightweight, ergonomic design with easy operation |
| Application | Professional testing and calibration of oscillometric NIBP monitors |
| Built-in Air Pump | Generates pressure up to 400 mmHg (53.3 kPa) |
| Testing Functions | Pressure leak test, over-pressure relief test, static pressure calibration, dynamic BP simulation |
| Patient Simulation | Simulates standard conditions and special patient conditions |
| Simulation Conditions | Weak pulse, obesity, geriatric patient, neonatal BP, wrist BP, exercise conditions |
| Arrhythmia Simulation | Supports arrhythmia condition simulation |
| Respiratory Interference | Supports respiratory interference simulation |
| User Settings | User-defined BP simulation parameters with storage capability |
| Operation Control | Power ON/OFF function and system parameter management |
| Parameter | Specification |
|---|---|
| Systolic Pressure Range | 20–300 mmHg (2.7–40.0 kPa) |
| Diastolic Pressure Range | 10–250 mmHg (1.3–33.3 kPa) |
| Pulse Volume | 0.1–2.4 cc |
| Simulation Type | Static and dynamic BP simulation |
| Parameter | Specification |
|---|---|
| HR Range | 30–250 bpm |
| Maximum HR (Pulse Volume >2.0 cc) | 200 bpm |
| Accuracy | ±1 bpm (excluding special simulation conditions) |
| Simulation Condition | Accuracy |
|---|---|
| Weak Pulse / Tachycardia / Obesity / Geriatric | ±(1% + 1 bpm) |
| Moderate Exercise | ±(1.5% + 1 bpm) |
| Intense Exercise | ±(3% + 1 bpm) |
| Parameter | Specification |
|---|---|
| Measurement Range | 0–400 mmHg (0–53.3 kPa) |
| Resolution | 0.1 kPa / 1 mmHg / 1 cmH₂O / 1 inH₂O / 0.1 psi |
| Accuracy (0–300 mmHg) | ±(0.5% reading + 1 mmHg) |
| Accuracy (301–400 mmHg) | ±2% of reading |
| Test Function | Description |
|---|---|
| Pressure Leak Test | Automatically generates pressure and calculates leakage rate |
| Leak Test Pressure | Up to 400 mmHg |
| Leak Calculation | Displays peak pressure, real-time pressure, and leak rate after test period |
| Over-Pressure Relief Test | Verifies NIBP safety valve release pressure |
| Pressure Source Output | 50–400 mmHg (6.7–53.3 kPa) |
| Pressure Deviation | ±10 mmHg within 100–400 mmHg range |
Compatible accessories to extend functionality
| Item | Quantity |
|---|---|
| S-bplink NIBP Simulator Main Unit | 1 Pcs |
| User Manual | 1 Pcs |
| Power Cord | 1 Pcs |
| Fuse | 1 Pcs |
| Item | Purpose |
|---|---|
| NIBP Monitor Connection Hose | Connect simulator with NIBP monitor |
| External NIBP Cuff | For testing with external cuff connection |
| Wrist NIBP Cuff | For wrist blood pressure monitor testing |
| 3-Port Connector (T-Type / Y-Type) | Connection between simulator, cuff, and monitor |
Core specifications at a glance