Searching…
    Home Company News and Events Meditech Neonate Wrap Oximeter Probe BCI Compatible
    Product Library

    Meditech Neonate Wrap Oximeter Probe BCI Compatible

    June 2026 2 min read

    Meditech Neonate Wrap Oximeter Probe "BCI Compatible" Model: XXXX  by Meditech     XXXX SpO2 pulse oximeter sensors are intended for continuous monitoring of arterial oxygen saturation and pulse rate




    Meditech Neonate Wrap Oximeter Probe “BCI Compatible”



    Model: XXXX  by Meditech

     

     

    XXXX SpO2 pulse oximeter sensors are intended for continuous monitoring of arterial oxygen saturation and pulse rate. The pulse oximeter SpO2 probes are compatible with BCI and Meditech pulse oximeters with SpO2 connectors. 

    All material that comes into contact with skin has passed the bio-compatibility test and can minimize the risk of skin allergies, cell cytotoxicity and stimulating.

    The XXX pulse oximeter sensor probe is for adults, children, infants and neonates. The sensor can be applied to multi-sites, including fingers or toes. By wrapping the SpO2 probe around an infant’s finger or toe, it makes taking measurements a lot easier.

    Recommended positions: Use lateral side of foot for 2~9lbs (1~4kg) patients; use big toe for >7lb (3kg); use big toe or finger for >22lbs(10kg).

     

    Neonate Wrap Oximeter Probe has two different types of connectors as shown in the diagram below 

    (left) and miniature D (right).

     

    Meditech SpO2 sensor (Wrap pulse oximeter sensor)

    WARNING: For continuous monitoring of a baby, the monitoring must be performed under adult constant supervision. The probe is not a toy and the baby must not be allow to tangle up with the cable. This is especially true when the infant is capable of pulling things and can move his body around. Attach the probe to his feet; run the cable towards the end of the bed away from his body; keep the cable out of the baby’s view; secure the cable so that he cannot grab the cable or tangle himself.

    One approach is to secure the cable onto the bed sheet using safety pins, cover the cable with another bed-sheet leaving only a few inches out for attaching the probe to the baby, and then tuck the ends of the both bed sheets firmly and tightly under the mattress.

     

    Technical Specifications

     

    • Measuring range for SPO2: 70-100%
    • SpO2 measurement accuracy: 90%–100%, ±1%; 70%–89%, ±2%; ≤70%, unspecified.
    • Storage temperature: -20°C to 50°C
    • Operation temperature: 5°C to 40°C
    • Relative humidity: 35% – 75%

     

    Share:

    More from News & Events

    View all articles
    Meditech library
    Meditech library Aug 2026

    MD901F vs MD901F-Android Fetal Maternal Monitor Comparison Table

      Parameter MD901F MD901F-Android Type 12.1 inch 12.1 inch Standard Configuration FHR, TOCO, FM FHR, TOCO, FM, Touch Screen, Networking…

    Read more 2 min
    Product Library
    Product Library Jun 2026

    iBreathe TOUCH SCREEN SPIROMETER med inbyggd skrivare

    iBreathe TOUCH SCREEN SPIROMETER med inbyggd skrivare Bärbar enhet för lungfunktionstestning Denna spirometer använder differentialtrycksteknik för att noggrant mäta över…

    Read more 2 min
    Product Library
    Product Library Jun 2026

    How AED pads are manufactured?

    How AED pads are manufactured The production of AED pads is a meticulous process involving several stages to ensure their…

    Read more 2 min