Home > Product list > Multiparameter Patient Monitor > Vital Sign Monitor > Oxima


        
Oxima  
Meditech compact vital signs monitor Oxima with pulse oximeter and NIBP measurement. High bright LED display of NIBP, SPO2 and pulse rate. adult, new-born infant probe available. Oxima is equipped with adjustable audible and visual alarms and built-in rechargeable battery, and it can store up to 2000 groups NIBP data which equals to 10 hours SpO2 data.








     




Oxima Patient Monitor adopts Oscillometry for NIBP measuring, Photoelectric Oxyhemoglobin Inspection Technology combining Capacity Pulse Scanning & Recording Technology for SpO2 measuring. Systolic Pressure (SYS), Diastolic Pressure (DIA), Mean Pressure (MAP), SpO2 and Pulse rate (PR) can be accurately measured.
Compact appearance, comprehensive functions, simple and convenient operation, which is applicable for hospitals, community medical treatment and family.

Features
  • Using  for adult, pediatric and neonatal for all-round monitoring, easy operation and high cost performance.
  • Built-in rechargeable Li-polymer battery for uninterrupted monitoring.
  • Compact and flexible appearance, easy for carrying and be suitable for indoor and outdoor(in ambulance) monitoring.
  • With user-friendly interface.
  • Display with 2.4'' (320240) color TFT LCD and blue highlight LED.
  • Visual and audible alarm for Systolic Pressure(SYS), Diastolic Pressure(DIA), Mean Pressure(MAP), SpO2 and Pulse rate(PR), and upper and lower limit of alarm can be set.
  • Unique Flash memory, storage for up to 2000 NIBP data or SpO2 data within 48-hour.
  • Convenient and quick in inquiring measurement data.
  • Optional parameter: temperature.
  • Uses  for medicine, surgery, operating room, ICU/CCU, emergency room, obstetrics and gynecology, pediatrics.

Performance
NIBP Monitoring
  • Measurement method: Oscillometry
  • Measurement mode: manual/auto/continuous.
  • Auto measurement interval: adjustable from 1 to 255 minutes.
  • Resolution: 1mmHg.
  • Accuracy: Maximum Mean deviationܡ5mmHg, Maximum Standard deviation8mmHg.
  • Self-check function.
  • Overpressure protection: double protection for software and hardware.
Adult:
              Systolic pressure: 40mmHg~270mmHg
              Mean pressure: 20mmHg~235mmHg
              Diastolic Pressure: 10mmHg~215mmHg
Pediatric:
              Systolic pressure: 40mmHg~200mmHg
              Mean pressure: 20mmHg~165mmHg
              Diastolic Pressure: 10mmHg~150mmHg
Neonatal:
              Systolic pressure: 40mmHg~135mmHg
              Mean pressure: 20mmHg~110mmHg
              Diastolic Pressure: 10mmHg~100mmHg
  • Upper and lower limit of alarm

SpO2 Monitoring 
  • Continuous real-time measuring.
  • Adopt digital SpO2 technology, which has strong anti-interference capability.
  • Real-time display SpO2, pulse rate, SpO2 Plethysmogram, bar graph, SpO2 and Pulse rate(PR) trend graph. Trend graph with the function of adaptive scaling. Standard adult finger-clip probe, binding probe for neonatal is optional.
  • Range: 35%~100% (Resolution: 1%)
  • Accuracy: 2% in stage of 70%-100%, and unspecified in stage of less than 70%.

Pulse Rate:
  • Range: 30bpm~250bpm(Resolution: 1bpm)
  • Accuracy: 2bpm or 2%, whichever is greater.
  • Measurement Performance in Weak Filling Condition: SpO2 and pulse rate can be shown 
  • correctly when pulse-filling ratio is 0.4%, SpO2 error is 4%; the Pulse rate error is 2bpm or 2%, whichever is greater.
  • Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than 1%.

Accessories
  • A Power Cord
  • A SpO2 Probe
  • An Adult BP Cuff
  • An Extending Tube For Blood Pressure


Dimensions and Weight
Dimension: 232(L)198(W)75(H)mm