MD9000s
|
|
Meditech MD9000s patient monitor has a 12.1"color TFT screen. With ECG, SP02, NIBP, RESP .2-TEMP. PR as standard parameters, and 2-IBP, ETC02 and thermal printer as options, MD9000s almost covers all the measurements of vital signs. A maximum 72 hours storage capacity can save for 500 units of NIBP measurement data, 72 alarm events and 32 seconds waveform for history review. |
|
|
|
|
- High resolution 12.1” color TFT display
- Light weight, compact and portable ECG, SP02, NIBP, RESP .2-TEMP. PR
- Built-in rechargeable lithium battery
- ECG waveforms of 7-leads display on the same screen
- 72-hours graphic and tabular trends of all parameters
- 72 alarm events of all parameters recall
- 32 seconds full-disclosure waveform review
- 500 NIBP measurement data can be storage and recall
- Data and waveforms color be adjustable
- Arrhythmia analysis and S-T segment analysis
-
Suitable for adult, pediatric and neonatal patient

Optional: 2-IBP, ETC02 and thermal printer
|
5-lead or 3-lead selectable
|
|
Input: 5-lead:
|
RA; LA; RL; LL; V or R; L; N; F; C
|
|
Lead selection:
|
I; II; III; avR; avL; avF; V
|
|
Gain selection:
|
x0.25; x0.5; x1; x2
|
|
Sweep speed:
|
12.5mm/s, 25mm/s, 50mm/s
|
|
Accuracy:
|
±1bpm or ±1%, whichever is greater
|
|
Protection:
|
Withstand 4000VAC/50Hz voltage
|
|
in isolation against electrosurgical interference and defibrillation
|
|
Calibration signal:
|
1mV±5%
|
|
Operation modes:
|
Diagnostic, Monitor, Surgery
|
|
Alarm range: Adult:
|
15-300bpm
|
|
Pediatric/Neonatal:
|
15-350bpm
|
|
S-T detection:
|
YES
|
|
Alarm range:
|
-2.0mV~2.0mV
|
|
Arrhythmia analysis:
|
YES
|
|
Alarm:
|
YES, audible and visual alarm, alarm events recallable
|
|
Method:
|
Oscillometry
|
|
Operation modes:
|
Manual/Automatic/STAT
|
|
Measurement unit:
|
mmHg/KPa selectable
|
|
Measurement types:
|
Systolic, Diastolic, Mean
|
|
Measurement range:
|
Adult: 10-270mmHg
|
|
Over-pressure protection:
|
YES
|
|
Resolution:
|
1mmHg
|
|
Accuracy:
|
Mean error and standard deviation per ANSI/AAMI SP-10
|
|
Alarm:
|
Systolic, Diastolic, Mean
|
|
Measurement range:
|
0-100%
|
|
Accuracy:
|
±2digit (70~100%);0~69% unspecified
|
|
Alarm range:
|
0-100%
|
|
Method:
|
RA-All impedance
|
|
Operation modes:
|
Manual/Automatic/STAT
|
|
Measurement unit:
|
mmHg/KPa selectable
|
|
Measurement types:
|
Systolic, Diastolic, Mean
|
|
Measurement range:
|
Adult: 0-270rpm,
Pediatric& neonatal: 0-150rpm
|
|
Resolution:
|
0.1℃
|
|
Channel:
|
Dual-channel
|
|
Alarm range:
|
0-50℃
|
|